| The new b maXX 5000 side-by-side converter
generation has an integrated Drive Connect- System: individual
modules can be easily added or removed without having to break
up the entire drive group. The standard-setting control quality
is maintained at all times.
With the newly developed b maXX 5000 drive generation, Baumüller
continues to set trends. The strategic development of the
successful b maXX series to encompass side-by-side technology
is a success due to high-performance power units with the
cooling type air and cold plate, flexible expansion capability,
and integration into a universal communication concept. Both
standardized and complex automation solutions are possible
with the new converters and controllers in the 1 to 35 kW
power range. The requirements for machines and plants in terms
of future-proofing, flexible expansion capability, and easy
adaptation to production process changes were taken into consideration
early on in the b maXX 5000 development process.
b maXX 5000 – Integrated safety concept instead
of add-on solution
 |
- Plug-in module, optionally with or without safety
functions
- Three different safety modules with scalable functionality
- All modules with integrated parameter memory
- Safety functions according to IEC 61800-5-2
- Power output for motor brake
- Choice of safety functions via local safe I/O or
EtherCAT FSoE
|
| Mains
rectifier unit |
DC
link power |
DC
link peak power1) |
Overload
factor |
Dimensions
air
WxHxD [mm] |
Dimensions
cold plate
WxHxD [mm] |
|
Frame
size |
Type |
[kW] |
[hp] |
[kW] |
[hp] |
| 3 |
5031 |
10 |
13,4 |
15 |
20,1 |
1,5 |
75 x 395 x 280 |
75 x 405 x 210 |
| 3 |
5032 |
18 |
24,1 |
27 |
36,2 |
1,5 |
75 x 395
x 280 |
75 x 405
x 210 |
| 4 |
5043 |
36 |
48,2 |
52 |
69,7 |
1,4 |
100 x 395
x 280 |
75 x 405
x 210 |
| 4 |
5044 |
70 |
93,8 |
70 |
93,8 |
1,3 |
100 x 395
x 280 |
75 x 405
x 210 |
| Active
Mains
regenerative
feedback unit |
DC
link power |
DC
link peak power1) |
Overload
factor |
Dimensions
air
WxHxD [mm] |
Dimensions
cold plate
WxHxD [mm] |
Frame
size |
Type |
[kW] |
[hp] |
[kW] |
[hp] |
| 4 |
5143 * |
36 |
48,2 |
52 |
69,7 |
1,4 |
100 x 395
x 280 |
100 x 405
x 210 |
| 7 |
5174 * |
64 |
87 |
96 |
130,2 |
1,5 |
175 x 395
x 280 |
100 x 405
x 210 |
| Axis
units |
I N
|
I MAX |
Typical
motor power 1) |
Overload
factor |
Dimensions
air
WxHxD [mm] |
Dimensions
cold plate
WxHxD [mm] |
Frame
size |
Type |
[A] |
[A] |
[kW] |
[hp] |
| 2 |
5323 |
2 x 3 |
2 x 9 |
2 x 1,6 |
2 x 2,1 |
3 |
50 x 395
x 280 |
50 x 405
x 210 |
| 2 |
5325 |
2 x 6 |
2 x 18 |
2 x 3,2 |
2 x 4,2 |
3 |
50 x 395
x 280 |
50 x 405
x 210 |
2 |
5326 |
12 |
24 |
6,5 |
8,7 |
2 |
50 x 395 x 280 |
50 x 405 x 210 |
2 |
5327 |
20 |
40 |
10,8 |
14,5 |
2 |
50 x 395 x 280 |
50 x 405 x 210 |
2 |
5328 |
30 |
60 |
16,2 |
21,7 |
2 |
50 x 395 x 280 |
50 x 405 x 210 |
3 |
5331* |
2 x 12 |
2 x 24 |
2 x 6,5 |
2 x 8,7 |
2 |
75 x 405 x 280 |
75 x 405 x 210 |
3 |
5332* |
2 x 20 |
2 x 40 |
2 x 10,8 |
2 x 14,5 |
2 |
75 x 405 x 280 |
75 x 405 x 210 |
3 |
5333* |
2 x 30 |
2 x 60 |
2 x 16,2 |
2 x 21,7 |
2 |
75 x 405 x 280 |
75 x 405 x 210 |
3 |
5334 |
40 |
60 |
21,6 |
29,0 |
1,5 |
75 x 395 x 280 |
75 x 405 x 210 |
3 |
5335 |
60 |
90 |
32,4 |
43,4 |
1,5 |
75 x 395 x 280 |
75 x 405 x 210 |
| Mains rectifier
unit, Active mains regenerative feedback unit: |
Axis units: |
| Supply voltage: |
207 V - 528 V +/- 0% AC |
Electronics supply: |
external 24 V DC |
| Supply frequency: |
50/60 Hz |
DC link voltage: |
540 V rated voltage |
| Electronics supply: |
external 24 V DC |
Clock frequency |
4/8 kHz |
| Rated supply voltage |
400 V |
Certification |
CE, cUL * |
| Rated DC link voltage: |
540 V (Mains rectifier unit)
640 V (Active mains regenerative feedback unit) |
1) For 150 seconds |
2) Load cycles acc. to EN 61800 |
| Certification: |
CE, cUL * |
* Available soon |