b maXX 4100
Rectifier and regenerative feedback unit b maXX 4100
| It is often the case with electrical drives
that energy costs make up almost 90% of the overall life-cycle
costs. With this in mind, regenerative systems help to reduce
the total cost of ownership.
 |
Baumüller’s
tried-and-tested b maXX automation and drive solution
is being expanded with the addition of the new b maXX
4100 series rectifier and regenerative feedback units.
These units supplement the b maXX 4400 series, supplying
one or more power modules and performing sinusoidal
brake energy feedback into the system.
As far as energy costs are concerned, this offers the
user the opportunity to make considerable savings over
the machine’s service life. Regenerative systems
also help to lower energy consumption (and do their
bit for the environment) by feeding the available brake
energy back into the system, rather than converting
it into heat via a regenerative resistor.
|
The b maXX 4100 units are fully integrated into Baumüller’s
b maXX automation and drive solution. The benefits which the
b maXX series offers to its users, i.e., modularity and flexibility,
are also provided by the b maXX 4100, thanks to the availability
of three different frame sizes covering a DC link power range
of 35 kW to 150 kW, the opportunity to select from various
cooling methods, such as air or water cooling, and the fact
that the b maXX 4100 can be integrated in the Baumüller
automation environment by means of various optional fieldbuses.
System continuity is ensured by using existing housing technology
and connection data, as well as by parameterizing the b maXX
4100 by means of the ProDrive
b maXX operating software that is already used.
- sinusoidal feedback of the brake energy into the
system
- three frame sizes from 35 kW to 150 kW
- air or water cooling
- 60 second overload capability
- current-controlled charging connection
- integrated control of charging and main contactors
- integrated regenerative transistor
- monitoring of system, charging connection, main
contactor, DC link voltage, and heat sink temperature
- optional fieldbus modules
|
|
|
frame
size 3
4
6
 |
| Frame
size |
Type |
DC link power
1)
[kW] [hp]
|
peak DC link
power
[kW] [hp]
|
overload
facto r 2) |
Dimensions
WxHxD 3) [mm] |
| 3 |
4135 |
35 |
47 |
52 |
70 |
1,5 |
155 x 510 x 340 |
4 |
4145 |
80 |
107 |
104 |
139 |
1,3 |
190 x 624 x 374 |
6 |
4163 |
150 |
201 |
195 |
255 |
1,3 |
437 x 815 x 378 |
| Supply
voltage: |
360 V -
528 V +/- 0% AC |
Regenerative
transistor: |
Integrated |
| Supply frequency: |
45-65 Hz |
Electronics supply: |
External 19,3 - 30
V DC (diagnostic capability) |
| Supply rated voltage: |
400 V AC |
Fan connection |
Frame size
3: 24 V DC electronic supply
Frame size 4-6: 230 V AC +/- 10% |
| DC link rated voltage: |
640 V DC |
Certification |
CE, CSA*, UL * |
| Clock frequency: |
8 kHz |
|
|
1) For 640 V DC DC link rated
voltage 2) For 60 seconds
3) Height and depth without mounting brackets; depth including
required bending radius of connecting cables
|
|
© Baumüller Nürnberg GmbH. All rights reserved.
|
|
|
|